10. EVERY 001 GENERAL CONDITIONS |
PPA - DEFINITIONS |
Status:
INEFFECT |
Conditions:
Informational |
The words identified in the following list that appear in all capitals in the attached conditions of Plot Plan No. 24286 shall be henceforth defined as follows:
APPROVED EXHIBIT A = Plot Plan No. 24286, Exhibit A, dated October 28, 2009. |
10. EVERY 002 GENERAL CONDITIONS |
PPA - PROJECT DESCRIPTION |
Status:
INEFFECT |
Conditions:
Informational |
| The use hereby permitted is convert existing 2,180 sq. ft. carport into a workshop/work area with temp controlled cooling room associated with the 1,260 sq. ft. residence with a 230 sq. ft. attached garage located at 39740 Via Carmelo in Temecula, CA. APN: 915-550-030. |
10. EVERY 003 GENERAL CONDITIONS |
PPA - HOLD HARMLESS |
Status:
INEFFECT |
Conditions:
Informational |
| The applicant/permittee or any successor-in-interest shall defend, indemnify, and hold harmless the County of Riverside COUNTY), its agents, officers, or employees from any claim, action, or proceeding against the COUNTY, its agents, officers, or employees to attack, set aside, void, or annul an approval of the COUNTY, its advisory agencies, appeal boards, or legislative body concerning PP24286. The COUNTY will promptly notify the applicant/ permittee of any such claim, action, or proceeding against the COUNTY and will cooperate fully in the defense. If the COUNTY fails to promptly notify the applicant/permittee of any such claim, action, or proceeding or fails to cooperate fully in the defense, the applicant/permittee shall not, thereafter, be responsible to defend, indemnify, or hold harmless the COUNTY. |
10.FIRE 001 GENERAL CONDITIONS |
USE-#50-BLUE DOT REFLECTOR |
Status:
INEFFECT |
Conditions:
Informational |
| Blue retroreflective pavement markers shall be mounted on private street, public streets and driveways to indicate location of fire hydrants. Prior to installation, placement of markers must be approved by the Riverside County Fire Department. |
10.FIRE 002 GENERAL CONDITIONS |
USE-#23-MIN REQ FIRE FLOW |
Status:
INEFFECT |
Conditions:
Informational |
| Minimum required fire flow shall be 1000 GPM for a 2 hour duration at 20 PSI residual operating pressure. |
10.FIRE 003 GENERAL CONDITIONS |
USE-#76-STANDARD FH 330/165 |
Status:
INEFFECT |
Conditions:
Informational |
| An Approved standard fire hydrant (6"x4"x2 1/2") shall be located at the driveway entrance. |
10.FIRE 004 GENERAL CONDITIONS |
USE-#25-GATE ENTRANCES |
Status:
INEFFECT |
Conditions:
Informational |
| ny gate providing access from a road to a driveway shall be located at least 35 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on the road. Where a one-way road with a single traffic lane provides access to a gate entrance, a 38 foot turning radius shall be used. |
10.FIRE 005 GENERAL CONDITIONS |
USE-#88A-AUTO/MAN GATES |
Status:
INEFFECT |
Conditions:
Informational |
| Gate(s) shall be automatic operated, minimum 20 feet in width, with a setback of 35 feet from face of curb/flow line. Gate access shall be equipped with a rapid entry system. Plans shall be submitted to the Fire Department for approval prior to installation. Automatic/manual gate pins shall be rated with shear pin force, not to exceed 30 foot pounds. Automatic gates shall be equipped with emergency backup power. Gates activated by the rapid entry system shall remain open until closed by the rapid entry system. |
10.FIRE 006 GENERAL CONDITIONS |
USE-#21-HAZARDOUS FIRE AREA |
Status:
INEFFECT |
Conditions:
Informational |
| This project is located in the "Hazardous Fire Area" of Riverside County as shown on a map on file with the Clerk of the Board of Supervisors. Any building constructed within this project shall comply with the special construction provisions contained in Riverside County Ordinance 787.1. |
10.FIRE 007 GENERAL CONDITIONS |
USE-#005-ROOFING MATERIAL |
Status:
INEFFECT |
Conditions:
Informational |
| All buildings shall be constructed with class B roofing material as per the California Building Code. |
10.PLANNING 002 GENERAL CONDITIONS |
PPA - LANDUSE APPROVAL ONLY |
Status:
INEFFECT |
Conditions:
Informational |
| The applicant or the applicant's successor in interest is notified through this condition that the approval granted on Plot Plan No. 24286, is for land use approval only, and has only met the requirements of Ordinance 348. Any requirements deemed necessary by another department or agency of Riverside County on a subsequent building permit are valid and may cause this approval by the Riverside County Planning Department as it stands to be rendered null and void or require significant revision. It is incumbent upon the applicant to research the acceptability of this proposal to all responsible departments and agencies prior to the acceptance of this approval. Responsible agencies include, but are not limited to the Fire Department, Environmental Health Department, the local Flood Control District, Building and Safety Department, Transportation Department, the Environmental Programs Department, the County Geologist, or the Transportation Land Management Agency. |
10.PLANNING 003 GENERAL CONDITIONS |
PPA - NO HOME OCCUPATIONS |
Status:
INEFFECT |
Conditions:
Informational |
No home occupations are permitted in an accessory structure or guest home.
From section 21.36 of Ordinance 348: Home Occupations:
Home occupations means those uses that are customarily conducted in a residence, provided such uses must be incidental and secondary to the principal use of a dwelling as a residence. The following criteria shall apply to any home occupation:
a. Except for large family day care homes which may require two assistants and small family day care homes which may require one assistant to be present in addition to the licensee or provider, no person other than a resident of the dwelling shall be employed on the premises in the conduct of a home occupation.
b. A home occupation shall be conducted entirely within the dwelling and shall be incidental and secondary to the use of the dwelling as a residence.
c. A home occupation shall not be conducted in an accessory structure and there shall be no storage of equipment or supplies in an accessory structure or outside building.
d. The residential character of the exterior and interior of the dwelling shall not be changed.
e. No vehicles or trailers except those normally incidental to residential use shall be kept on the site.
f. No signs other than one unlighted identification sign, not more than two square feet in area, shall be erected on the premises. |
10.PLANNING 004 GENERAL CONDITIONS |
PPA - ACSRY STRC NO HBTBL AREA |
Status:
INEFFECT |
Conditions:
Informational |
| No habitable area has been approved with this approval. The addition of habitable area will require additional approvals. |
10.PLANNING 005 GENERAL CONDITIONS |
PPA - SETBACKS IN HIGH FIRE |
Status:
INEFFECT |
Conditions:
Informational |
Please be advised that the setbacks for structures within a County designated high fire areas have increased. It is advisable prior to the purchase of structure or prior to planning of a structure (such as hiring an architect or engineer to create plans) that the applicant should contact the Fire Department to make sure that the structure question meets those requirements.
Fire Department Planning 2300 Market Street, Suite 150 Riverside, CA 92501 951-955-4777 |
20.PLANNING 001 PRIOR TO A CERTAIN DATE |
PPA - EXPIRATION DATE-PP |
Status:
INEFFECT |
Conditions:
Outstanding |
| This approval shall be used within two (2) years of approval date; otherwise, it shall become null and void and of no effect whatsoever. By use is meant the beginning of substantial construction comtemplated by this approval within a two (2) year period which is thereafter diligently pursued to completion or to the actual occupancy of exisiting buildings or land under the terms of the authorized use. Prior to the expiration of the two year period, the permittee may request a one (1) year extension of time request in which to use this plot plan. A maximum of three one-year extension of time requests shall be permitted. Should the time period established by any of the extension of time requests lapse, or should all three one-year extensions be obtained and no substantial construction or use of this plot plan be initiated within five (5) years of the effective date of the issuance of this plot plan, this plot plan shall become null and void. |
20.PLANNING 002 PRIOR TO A CERTAIN DATE |
PPA - EXISTING STRUCTURE (1) |
Status:
INEFFECT |
Conditions:
Outstanding |
| WITHIN SIXTY (60) DAYS OF THE EFFECTIVE DATE OF THIS PERMIT, the permittee or the permittee's successors-in- interest shall apply to the Building and Safety Department for all necessary permits, including the submission of all required documents and fees for any plan check review as determined by the Director of the Department of Building and Safety, to ensure that all existing buildings, structures and uses are in compliance with Ordinance No. 348 and Ordinance No. 457 and the conditions of approval of this permit. |
80.FIRE 001 PRIOR TO BLDG PRMT ISSUANCE |
USE-#4-WATER PLANS |
Status:
INEFFECT |
Conditions:
Outstanding |
| The applicant or developer shall separately submit two copies of the water system plans to the Fire Department for review and approval. Calculated velocities shall not exceed 10 feet per second. Plans shall conform to the fire hydrant types, location and spacing, and the system shall meet the fire flow requirements. Plans shall be signed and approved by a registered civil engineer and the local water company with the following certification: "I certify that the design of the water system is in accordance with the requirements prescribed by the Riverside County Fire Department." |
80.PLANNING 001 PRIOR TO BLDG PRMT ISSUANCE |
PPA - CONFORM TO ELEVATIONS |
Status:
INEFFECT |
Conditions:
Outstanding |
| Elevations of all buildings and structures submitted for building plan check approval shall be in substantial conformance with the elevations shown on APPROVED EXHIBIT B, dated October 28, 2009. |
80.PLANNING 002 PRIOR TO BLDG PRMT ISSUANCE |
PPA - CONFORM TO FLOOR PLANS |
Status:
INEFFECT |
Conditions:
Outstanding |
| Floor plans shall be in substantial conformance with that shown on APPROVED EXHIBIT C, dated October 28, 2009. |
80.PLANNING 003 PRIOR TO BLDG PRMT ISSUANCE |
PPA - EXISTING STRUCTURE |
Status:
INEFFECT |
Conditions:
Outstanding |
| PRIOR TO BUILDING PERMIT ISSUANCE, the permittee or the permittee's successors-in- interest shall apply to the Building and Safety Department for all necessary permits, including the submission of all required documents and fees for any plan check review as determined by the Director of the Department of Building and Safety, to ensure that all existing buildings, structures and uses are in compliance with Ordinance No. 348 and Ordinance No. 457 and the conditions of approval of this permit. |
90.FIRE 001 PRIOR TO BLDG FINAL INSPECTION |
USE-#27-EXTINGUISHERS |
Status:
INEFFECT |
Conditions:
Outstanding |
| nstall portable fire extinguishers with a minimum rating of 2A-10BC and signage. Fire Extinguishers located in public areas shall be in recessed cabinets mounted 48" (inches) to center above floor level with maximum 4" projection from the wall. Contact Fire Department for proper placement of equipment prior to installation. |